Product Description
Full Text Search
 

To Download EDS3-128 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ?output signals: each signal within range from 4 to 20 ma dc non-isolated (isolated output available at option) co instantaneous value o 2 instantaneous value moving average co value after o 2 cor- rection (averaging time variable) time setting in 1 to 59 minutes (1-minute increment) or 1 to 4 hours (1-hour incre- ment) allowable load resistance 550 ? or less ?pump on/off contact input: no voltage contact (closed: pump on) ?indication: lcd with back light for indicating co in- stantaneous value, o 2 instantaneous value, co instantaneous value after o 2 correction and co average values after o 2 correction, o 2 average value (1-hour and time-variable averaging) and param- eter assignment ?recorder (option): 100 mm-width recorder (fuji electric? type phc or phe) built in, max. 6 points recordable ?gas extractor: general type (without filter) titanium probe (300, 400, 600 or 800 mm long) flange jis 5k25aff weight: approx. 1 kg (800 mm) electrical heating type (filter built in) filter mesh; 40 m mesh of sus 316 stainless steel probe; sus 316 stainless steel of 300, 400, 600 or 800 mm length flange; jis 5k65aff weight; approx. 8.5 kg ?measuring system: non-dispersive infrared absorption (ndir) method for co galvanic method for o 2 ?measurable component and range: co ; 0~500/1000ppm 0~500/2000ppm o 2 ; 0~25vol% ?repeatability: 0.5% of full scale/co 1% of full scale/o 2 ?zero drift: max. 2.0% of full scale/month for co max. 2.0% of full scale/week for o 2 ?span drift: max. 2.0% of full scale/week for co max. 2.0% of full scale/month for o 2 ?linearity: max. 2.0% of full scale ?sample gas extracting rate: approx. 0.4 r /min ?response time: within 150 seconds for 90% indication (after extracting sample gas through the inlet) ?warm-up time: within 4 hours after power-on this instrument is equipped with a non-dispersive infrared co sensor and a galvanic oxygen sensor and used for measuring co and o 2 in the gas emitted from garbage in- cinerators. co instantaneous value, o 2 instantaneous value and co average value after o 2 correction (1-hour and time-variable averaging) can be output. specifications features data sheet zs w co/o 2 gas analyzer for stack gas 1. the co sensor adopts high-performance and long-life non- dispersive infrared ray (ndir) system. the co sensor is not consumable, and need not be replaced in 1 or 2 years. 2. automatic calibration function by air equipped as stan- dard allows stable measurement. no need to worry about the consumption of standard gas. 3. space-saving configuration unitized into 19-inch type al- lows the maintenance from the front. 4. a microjet recorder (fuji electric? type phc or phe) can be built in for recording measured gas concentration and temperature values. date EDS3-128 feb. 20, 2004
zs w 2 c s (21 ? o n ) 21 ? o s calculating equation: c = ?gas analyzer system ?specified external drain separator ?specified gas extractor/probe set ?specified gas inlet tube set ?specified standard gas (with pressure adjustor) set ?specified recorder to be accommodated in cubicle ?standard accessory set scope of delivery 1. code symbols 2. necessity of spares for 1-year measurement 3. type of recorder (option) type for 6-point continuous recording type: phc62043-na0yy-b scale specifications: 0 to 500ppmco, tk7k0750c2 for 2-point continuous recording type: phe2bb12-660ny-b scale specifications: 0 to 500ppmco, tk7k0750c4 ordering information ?separate extraction point filter: glass wool filter (for general type) container material: pvc ?sample inlet tube: 10/ 8 teflon tube or heating tube (max. 30 m) ?functions: 1) o 2 conversion and averaging calculation conversion of measured co gas concentration into a value at standard o 2 concentration c; co concentration after o 2 correction c s ; measured co concentration o s ; measured o 2 concentration (%) o n ; standard o 2 concentration (12% for garbage incinerator) moving average calculation time calculation is made for 1 to 59 minutes or 1 to 4 hours. 2) auto calibration (of co zero and o 2 span) auto calibration cycle settable range: 1 to 99 hours (1-hour step) or 1 to 40 days (1-day step) need 7 days set to keep drift spec. 3) output hold function holds output signal during auto calibration. 4) other functions temperature input signal: k thermocouple input x 2 (in- put for recorder) ?standard requirements for sample gas: ?temperature; 60 to 800?c ?dust; 0 to 300mg/nm 3 or less ?0 to 50mg/nm 3 : use general type extrac- tor. ?0 to 150mg/nm 3 : use general type extrac- tor with separate extrac- tion point filter. ?0 to 300mg/nm 3 : use heating extractor. ?pressure; ? to +2kpa ?components; so 2 500 ppm or less nox 1000 ppm or less co 2 0 to 15% co 0 to 2000 ppm o 2 0 to 21% hc r 1000 ppm or less n 2 , h 2 o remaining per- cent ?rated operating conditions: ?ambient temperature; 0 to +40 c or -5 to 40 c, -10 to 40 c ?ambient humidity; 90% rh or less ?power supply voltage; 100 v ac 10 v, 50 or 60 hz, 115 v ac 10% 60 hz, 230 v ac 10% 50 hz ?power supply frequency; rating 0.5 hz ?power consumption; max. 400 va (without gas extractor) ?installation requirements: 1) selection of a place which does not receive direct sunlight or radiation from hot substances 2) avoidance of a place under heavy vi- bration 3) clean atmospheric air ?external dimensions (h x w x d): indoor type 1550 x 600 x 650 mm outdoor type 1640 x 615 x 765 mm ?weight: approx. 180 kg (excluding standard gas) ?cubicle finish color: munsell 5y7/1 semi-gloss ?other: one standard gas (3.4 r ) cylinders accommodable (2 cylinders accommodable)
3 - 1 w s z 2 1 345678 - 10 9111213 15 14 16 17 description power supply (6th code) ac 100v 50hz ac 100v 60hz ac 115v 60hz ac 230v 50hz measurement range (5th code) 0~500 / 1000 ppmco 0~25% o 2 0~500 / 2000 ppmco 0~25% o 2 (note 1) specify when the inclination of the gas inlet tube from the gas extraction point to the gas inlet of the main unit is less than 15 downward. if there is a possibility of freezing, separately take measures against freezing. (note 2) recorder assignment is as follows. in 6-point recording: ch1; co instantaneous value ch2; o 2 instantaneous value ch3; vacant ch4; 1-hour average co value after o 2 correction ch5; k thermocouple 1 ch6; k thermocouple 2 in 2-point recording: ch1; average co value after o 2 correction ch2; o 2 instantaneous value phe of 2-point continuous recording type only can be specified. c d indication (4th code) japanese english 1 3 cubicle structure (7th code) indoor type outdoor type indoor type outdoor type indoor type outdoor type 1 2 a b c d 3 4 6 7 recorder (11th code) not provided with 6-point recorder phc with 2-point recorder phe y c e isolated output (12th code) non-isolated output isolated output (3 outputs) 0 3 fluorescent lamp (13th code) not provided provided y 1 standard gas (14th code) not provided co/n 2 (3.4l, cylinders 1) 1 4 gas extractor, flange dimension (15th code) without gas extractor general type, flange jis 5k 25a ff general type (with separate extraction point filter), flange jis 5k 25a ff heating extractor, flange jis 5k 65a ff y 1 2 3 gas extractor insertion length (16th code) without gas extractor 300mm 400mm 600mm 800mm y a b c d sample inlet tube type length (17th code) not provided not provided 10/ 8 teflon tube 5m 10/ 8 teflon tube 10m 10/ 8 teflon tube 15m 10/ 8 teflon tube 20m 10/ 8 teflon tube 25m 10/ 8 teflon tube 30m heating tube 10m heating tube 15m heating tube 20m heating tube 25m heating tube 30m y a b c d e f g h j k l gas pressure at extraction point (9th code) 2~+2kpa 4 external drain separator (10th code) not provided provided (note 1) y a temperature of installation site : 0 c or higher temperature of installation site : 5 c or higher temperature of installation site : 10 c or higher (note 2) (recorder hardware needs to be ordered simultaneously.) specify when the ambient temperature may fall to 5 ? c or lower (note) (note) specify heating extractor. code symbols
zs w 4 solenoid pump: operated at the time of calibration (atmo- spheric aspiration) gas aspirator: aspirates sample gas (approx. 0.4l/min.) needle valve: adjusts sample gas flow rate. electronic gas cooler: dehumidifies sample gas. membrane filter: removes minute dust. flow checker: monitors flow rate. standard gas (co/co 2 ): for co span and o 2 zero calibration pressure adjuster: depressurizes standard gas. gas extractor: extracts sample gas. general type (without filter), used when dust concentration is 50mg/nm 3 or lower. general type (with separate extraction point filter): used when dust concentra- tion is 150mg/nm 3 or lower. heating type (with filter, filter diameter: 40 ): used when dust concentration is 300mg/nm 3 or lower. extraction point filter: removes dust. used when dust concen- tration is in the range from 50 to 150mg/ nm 3 mist filter: removes dust and mist. safety drain trap: functions to prevent suction of drain pot and drain. (suction prevention operating pressure: 6kpa, water seal pressure: approx. 2kpa) gas extractor gas aspirator sampling module electronic gas cooler membrane filter 0 to 90 extraction point filter (option) 15 or more sample gas inlet mist filter air inlet rc1/4 drain rc1/4 safety drain trap 2-direction solenoid valve solenoid pump 2-direction solenoid valve (with filter) co zero o 2 span needle valve flow checker (0.4l/min) co span o 2 zero co/ n 2 pressure adjuster 3.4l standard gas infrared co sensor galvanic o 2 sensor gas outlet rc1/4 functions of individual components
5 name 2 sheets general extractor or without extractor type of extractor filter paper for membrane filter (spare) 2 fuse with nail (3a) 1 standard gas joint 6 hose band for fixing standard gas cylinder 1 toalon tube for standard gas connection, 0.3m and 9/ 6mm 1 polyethylene tube for standard gas connection, 1m and 6/ 4mm 1 fixed restrictor for standard gas connection 1 water bottle for injection 1 pc. or none gas extractor flange packing 1 set or none gas extractor fastening bolt and nut o-ring (g50) for gas extractor (spare) heating tube support (only when heating tube is provided) 1 copy instruction manual 2 sheets general extractor with extraction point filter 2 1 6 1 1 1 1 1 pc. 1 set 1 copy 2 sheets heating extractor 2 1 6 1 1 1 1 1 pc. 1 set 1 1 set 1 copy extraction point filter fastening bolt and nut 1 set standard accessories spare parts for 1-year measurement 4 fuse (3a) 2 element for mist filter 2 o-ring (g65) for mist filter 1 diaphragm for gas aspirator 1 gas aspirator valve filter for extraction point filter o-ring (g65) for extraction point filter mesh filter for heating extractor packing for heating extractor seal metal packing for heating extractor o-ring (g50) for heating extractor 4 2 2 1 1 12 2 4 2 2 rubber ring for membrane filter 2 o-ring (g65) for membrane filter 2 2 2 2 2 1 1 1 1 pc. 1 pc. 1 name zbn1sw12 general extractor or without extractor type of extractor type 1 bag filter paper for membrane filter (25 sheets) zbn1sw22 general extractor with extraction point filter 1 bag zbn1sw32 heating extractor 1 bag recorder (option) standard accessory: ink cartridge 1 recording paper 1 roll spares for 1 year: phe type recorder ink cartridge (type: phzh2002) 2 recording paper (type: pex00dl1-5000b) 12 rolls phc type recorder ink cartridge (type: phzh1002) 2 recording paper (type: pex00dl1-5000b) 12 rolls
zs w 6 connection diagram 1 1 2 3 4 5 6 7 8 9 10 11 12 + + + 2 3 4 5 6 7 8 9 10 11 12 terminal block tb1 tb2 100v ac main power supply ground option (heating extractor) option (heating tube) analog output co instantaneous value analog output o 2 instantaneous value + analog output (co average value after correction) pump on/off contact input (dry) (closed: pump on) temperature input 2 temperature input 1 internal connection (m4 screw) 13 + + 14 15 16 outline diagram (unit: mm) anchor plan and door opening diagram front side rear side anchor bolt 420 610 32 35 door (4-m12 160 50) 3- 34 (with grommet) (waterproofing measures with through wire metal, etc. required for outdoor specifications.) 4- 15 front view left side view 765 (for outdoor use) 100 100 300 exhaust port rc1/4 air inlet rc1/4 drain rc1/4 sample gas inlet (with through connector for 10 teflon tube) 1295 170 610 650 (675) 70 70 70 150 615 1640 (for outdoor use) 1550 100 420 600
7 outline diagram (unit: mm) gas outlet rc 1 /2 cover 155 155 130 27 4-f15 (750) (76) 300, 400, 600, 800 (insertion length depends on code symbol.) 357 210 297 terminal box rc 3 /4 flange jis 5k 65a ff sampling pipe 20a gas inlet (309.5) cable hole g 1 /2 100v ac, 100w handle exchange filter heating tube support (mounted for heating tube specifications.) up
zs w gas outlet (with joint for rc1/2) ( 10/ 8 teflon tube) 75 95 flange jis5k 25a ff 4- 12 (even) insertion length depends on code symbols. approx.67 sampling pipe 15a gas inlet 10 33 inlet outlet maintenance space 200 18 10 30 60 55 80 2-mtg. holes 7 dia. joint for 10/ 8 teflon tube 2-rc 1 /4 clear gas outlet gas inlet 25 100 100 150 55 105 16 information in this catalog is subject to change without notice. printed in japan head office 6-17, sanbancho, chiyoda-ku, tokyo 102-0075, japan http://www.fesys.co.jp/eng sales div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http: //www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS3-128

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X